Back to: Incubators

Thermo Forma Steri-Cycle i160 Double-Stack CO2 Incubator

PDFPrintEmail
On roller base (identical to Thermo Heracell Vios 160i).
ThermoFormaSteriCyclei160dsCO2incubator_
ThermoFormaSteriCyclei160dsCO2incubator_3
Description

The exclusive "Steri-Run" high temperature sterilization cycle included with this incubator reaches 180°C on all chamber surfaces and is independently proven to achieve total sterilization and a 12 log Sterility Assurance Level (SAL). With the push of a button, the simple overnight routine provides fast, easy elimination of microbial contaminants and eliminates the need for separate autoclaving of parts. Additionally, the i160’s protected humidity reservoir boasts a directly heated water reservoir which provides stable high relative humidity levels, preventing culture desiccation. This allows for up to five times faster humidity recovery than traditional water pan designs.

 

Also featured is in-chamber HEPA filtration, which continuously filters the entire chamber air volume every 60 seconds. ISO 5 clean room air quality is achieved in the culture chamber within 5 minutes. Continuous protection is provided by minimizing the ability for contaminants to settle on interior surfaces.


Specifications
Temperature Range:Ambient +3°C to 55°C
Temperature Uniformity:± 0.3°C at 37°C
Temperature Stability:± 0.1°C at 37°C
CO2 Range:1 to 20%
CO2 Control Deviation:± 0.1%
CO2 Accuracy:± 0.3%
CO2 Sensor Type:TC
Required Gas Pressure:Minimum of 0.8 bar to maximum of 1 bar (12 to 15 PSI)
Relative Humidity:> 93% at 37°C
Volume:5.8 cu ft. (165L) [Per Unit]
Sterilization Cycle Temperature:180°C on all internal surfaces
Sterilization Cycle Duration:Under 12 hours
Access Port Diameter:1.6 in. (42 mm)
Data Outputs:Remote alarm contacts and USB
Shelf Dimensions (W x D):16.7 x 18.3 in. (42.3 x 46.5 cm)
Internal Dimensions (W x H x D):18.5 x 23.9 x 22.7 in. (47 x 60.7 x 57.6 cm) [Per Unit]
External Dimensions (W x H x D):25.1 x 35.4 x 34.6 in. (63.7 x 90 x 88 cm) [Per Unit]
Weight:183 lb. (83 kg.) [Per Unit]
Electrical Requirements:120V, 50/60 Hz, 8.3A, 1000W [Per Unit]

Comes with our 90-day warranty.

Biotech Equipment Sales, Inc.: based in South San Francisco, the Biotech capital of the world, since 2009. We are dedicated to bringing high-quality pre-owned laboratory instrumentation to our scientific community.

Biotech Equipment Sales, Inc.
226 Miller Ave.
South San Francisco, CA  94080
650-871-5707 office
650-276-7487 fax
sales@biotechequipmentsales.com